65
5 Parameter description
5.2 Query commands for basic setting
5.2.2 Configuration of fault pin and digital inputs
Command
Argument
Function
Description
IOC
–
I/O Configuration
Set input/output configuration.
Return value binary coded (LSB=Bit 0):
Bit 0-7, Hard Blocking:
0-31: Function active for input 1-5
Bit 8-15, Hard Polarity:
0-31: Rising edge at input 1-5
Bit 16-23, Hard Direction:
0-31: Clockwise rotation stored at input 1-5
Bit 24, State of digital output:
0: Low
1: High
Bit 25, Level of digital inputs:
0: TTL level (5V)
1: PLC LEVEL (24 V)
Bit 26-28, Function of fault pin:
0: ERROUT
1: ENCOUT
2: DIGOUT
3: DIRIN
4: REFIN
GDCE
–
Get Delayed
Current Error
Set value of the error output delay (DCE)
GPN
–
Get Pulse Number Set pulse number (LPN)
5.2.3 Configuration of homing
Command
Argument
Function
Description
HOC
–
Homing Configura-
tion
Set homing configuration.
Return value binary coded (LSB=Bit 0):
Bit 0-7, SHA setting
Bit 8-15, SHN setting
Bit 16-23, SHL setting
Bit 24, Power-On Homing Sequence
0: deactivated
1: activated (homing after power-on)
GHOSP
–
Get Homing Speed Set homing speed in rpm (HOSP)