61
5 Parameter description
5.2 Query commands for basic setting
5.2.1 Operating modes and general parameters
Command
Argument
Function
Description
CST
–
Configuration
Status
Set operating mode.
Return value is binary encoded
(LSB = Bit 0):
Bit 0, Compatible mode
0: COMPATIBLE0
1: COMPATIBLE1
Bit 1–2: Automatic responses
0: ANSW0 (no automatic responses)
1: ANSW1 (asynchronous responses)
2: ANSW2 (additional command acknowledgements)
3: ANSW3 (Debug)
Bit 3-4, Velocity presetting:
0: SOR0 (RS232 interface)
1: SOR1 (Analog voltage)
2: SOR2 (PWM signal)
3: SOR3 (current limitation value)
Bit 5-6, reserved
Bit 7-9, FAULHABER mode:
0: CONTMOD
1: STEPMOD
2: APCMOD
3: ENCMOD / HALLSPEED
4: ENCMOD / ENCSPEED
5: GEARMOD
6: VOLTMOD
7: IXRMOD
Bit 10, Power amplifier:
0: Disabled (DI)
1: Enabled (EN)
Bit 11, Position controller:
0: Switched off
1: Switched on
Bit 12, Analog direction of rotation:
0: ADL
1: ADR
Bit 13, Position Limits APL:
0: deactivated
1: activated
Bit 14, Sinus commutation SIN:
0: Allow block commutation
1: Do not allow block commutation
Bit 15, Network operation
0: NET0 (Single device on an RS232)
1: NET1 (Multiplex mode activated)
GMOD
–
Get Mode
MCDC
D
S
A
–
–
G
V
I
MCBL/
3564K024B CS
c
s
a
h
e
g
v
–
Set FAULHABER mode
CONTIMOD
STEPMOD
APCMOD
ENCMOD
ENCSPEED
GEARMOD
VOLTMOD
IxRMOD