16
3 Installation
3.3 Connector pin assignment
Depending on their type, Motion Controllers are equipped with either screw-type terminal strips or
pin headers as connection options. The 3564K024B CS motor is equipped with an eight-core connec-
tion cable (AWG 24).
Electronic damage / ESD protection
Electrostatic discharges at the Motion Controller's connections can cause destruction of the
electronics.
Note and follow the ESD protective measures.
Incorrect connection of the cores can cause damage to or destruction of the electronics.
Connect the connections in accordance with the connector pin assignment, see table.
Please also note the additional instructions on installation in Chapter 9 "EMC".
Power supply connections (+24 V, GND)
Malfunctions can occur if an inadequately dimensioned power pack is used. If the supply leads are
incorrectly connected (polarity reversal) the internal fuse trips.
This must be replaced in the factory!
The power pack should be adequately dimensioned for the connected motor.
Be sure to connect motor supply terminals to the correct polarity.
3.3.1 3564K024B CS
The connections are executed as coloured stranded wires and assigned as follows:
Wires
Designation
Meaning
blue
GND
GND
pink
+24 V
+24 V
brown
AnIn
Analog input
white
Fault
Error output
grey
AGND
Analog GND
yellow
RxD
RS232 RxD
green
TxD
RS232 TxD
red
3.In
3rd input
optional electronic supply U
B
3.3.2 MCBL 3003/06 S
The connections are indicated on the terminal strips and are assigned as follows:
Connector pin assignment, supply end
Connection Designation
Meaning
1
TxD
RS232 TxD
2
RxD
RS232 RxD
3
AGND
Analog GND
4
Fault
Error output
5
AnIn
Analog input
6
+24 V
+24 V
7
GND
GND
8
3. In
3rd input
optional electronic supply U
B
CAUTION!
CAUTION!