DLQ-3000+
Rev. A
3-14
3.2.6.2 HP (Home Position) Sensor Assembly Removal
Step 1) Remove the printer mechanism. (See Section 3.2.6.1.)
Step 2) Release the hooks securing the HP sensor assembly to the CR frame, and remove
the sensor.
H P S e n s o r A s s e m b l y
C R F r a m e
Figure 3-13. HP Sensor Removal
3.2.6.3 Front Paper Sensor Removal
Step 1) Remove the printer mechanism. (See Section 3.2.6.1.)
Step 2) Release the joint for the detection lever and the front paper sensor, and release
the hook securing the front paper sensor to the right frame assembly in the printer
mechanism. Then remove the front paper sensor.
P a p e r E j e c t F r a m e
D e t e c t i o n L e v e r
F r o n t P a p e r S e n s o r
R i g h t F r a m e A s s e m b l y
Figure 3-14 Removal. Front Paper Sensor Removal
Summary of Contents for DLQ-3000 Minerva+
Page 1: ...EPSON 24 PIN DOT MATRIX PRINTER EPSON DLQ 3000 SERVICE MANUAL SEIKO EPSON CORPORATION 4008259 ...
Page 5: ...v REVISION SHEET Revision Issued Data Contents Rev A August 21 1997 First Release ...
Page 61: ...2 3 12 Other Sensor Circuits 2 31 ...
Page 160: ...Chapter 6 Maintenance 6 1 Maintenance 6 1 6 1 1 Lubrication and Adhesion 6 1 ...
Page 171: ...DLQ 3000 Rev A A 6 ...
Page 172: ...Appendix Rev A A 7 A 2 Circuit Diagrams Figure A 2 C210 MAIN Board Circuit Diagram 1 2 ...
Page 173: ...DLQ 3000 Rev A A 8 ...
Page 174: ...Appendix Rev A A 9 Figure A 3 C210 MAIN Board Circuit Diagram 2 2 ...
Page 175: ...DLQ 3000 Rev A A 10 ...
Page 177: ...DLQ 3000 Rev A A 12 Figure A 5 C124 PSB Board Circuit Diagram ...
Page 180: ...Appendix Rev A A 15 Figure A 8 C210 MAIN Board Component Layout 2 2 ...
Page 181: ...DLQ 3000 Rev A A 16 Figure A 9 C124 PSB Board Component Layout ...
Page 182: ...Appendix Rev A A 17 Figure A 10 C124 PSE Board Component Layout ...
Page 189: ...EPSON SEIKO EPSON CORPORATION ...