Disassembly and Assembly
Rev. A
3-5
3.2.1.2 Ribbon Mask Removal
This section describes how to remove the ribbon mask holder which must be removed when
adjusting the platen gap. (Refer to Chapter 4 Adjustment.)
Step 1) Remove the printhead. (See Section 3.2.1.1.)
Step 2) Release the harnesses for the PEW sensors from the cable clamp.
Step 3) Flip the paper eject lever assembly toward the front.
Step 4) Widening the right and left tabs at the rear of the ribbon mask holder, remove the
ribbon mask holder by shifting it forward.
Step 5) Remove the ribbon mask from the ribbon mask holder.
CR Assembly
Mask Ribbon
Mask Ribbon Holder
Paper Eject Lever Assembly
Tubs
Figure 3-3. Ribbon Mask Holder Removal
Summary of Contents for DLQ-3000 Minerva+
Page 1: ...EPSON 24 PIN DOT MATRIX PRINTER EPSON DLQ 3000 SERVICE MANUAL SEIKO EPSON CORPORATION 4008259 ...
Page 5: ...v REVISION SHEET Revision Issued Data Contents Rev A August 21 1997 First Release ...
Page 61: ...2 3 12 Other Sensor Circuits 2 31 ...
Page 160: ...Chapter 6 Maintenance 6 1 Maintenance 6 1 6 1 1 Lubrication and Adhesion 6 1 ...
Page 171: ...DLQ 3000 Rev A A 6 ...
Page 172: ...Appendix Rev A A 7 A 2 Circuit Diagrams Figure A 2 C210 MAIN Board Circuit Diagram 1 2 ...
Page 173: ...DLQ 3000 Rev A A 8 ...
Page 174: ...Appendix Rev A A 9 Figure A 3 C210 MAIN Board Circuit Diagram 2 2 ...
Page 175: ...DLQ 3000 Rev A A 10 ...
Page 177: ...DLQ 3000 Rev A A 12 Figure A 5 C124 PSB Board Circuit Diagram ...
Page 180: ...Appendix Rev A A 15 Figure A 8 C210 MAIN Board Component Layout 2 2 ...
Page 181: ...DLQ 3000 Rev A A 16 Figure A 9 C124 PSB Board Component Layout ...
Page 182: ...Appendix Rev A A 17 Figure A 10 C124 PSE Board Component Layout ...
Page 189: ...EPSON SEIKO EPSON CORPORATION ...