Parameter Tables
- 68 -
Table 9: Parameter list - Distance Axis Backgauge
Table 10: Parameter list - Distance Axis Gap
Table 11: Parameter list - Distance Axis Angle
Function
Setting Range
Factory Setting
Customer Setting
Creep speed
0.0 … 1000.0
10.0
Tolerance window
0.0 … 100.0
0.1
Spindle compensation
0.0 … 1000.0
5.0
Reference value
-10000.0 … 100000.0
30.0
End position min
0.5 … 99999.0
3.0
End position max
0.5 … 99999.0
1101.0
Correction stop forwards
0.0 … 1000.0
0.1
Manipulation
0.0 … 100.0
0.1
Forced loop
0.0 … 1000.0
1.0
Factor
0.000001 … 1.000000
0.002500
Retract length
0.0…1000.0
1.0
Function
Setting Range
Factory Setting
Customer Setting
Creep speed
0.0 … 1000.0
5.00
Tolerance window
0.0 … 100.0
0.02
Spindle compensation
0.0 … 1000.0
0.10
Reference value
-10000.0 … 100000.0
00.0
End position min
0.05 … 99999.0
0.05
End position max
0.05 … 99999.0
5.00
Correction stop forwards
0.0 …1000.0
0.02
Manipulation
0.0 … 100.0
0.02
Forced loop
0.0 … 1000.0
0.10
Factor
0.000001 … 1.000000
1.000000
Retract length
0.0 … 1000.0
0.00
Function
Setting range
Factory setting
Customer setting
Creep speed
0.0 … 1000.0
3.00
Tolerance window
0.0 … 100.0
0.02
Spindle compensation
0.0 … 1000.0
0.10
Reference value
-10000.0 … 100000.0
00.0
End position min
0.05 … 99999.0
0.5
End position max
0.05 … 99999.0
1.50
Correction stop forwards
0.0 … 1000.0
0.02
Manipulation
0.0 … 100.0
0.00
Forced loop
0.0 … 1000.0
0.00
Factor
0.000001 … 1.000000
0.001000
Retract length
0.0 … 1000.0
0.00
Summary of Contents for P40T-002 Series
Page 49: ...Service Mode Parameter Level 49 11 11Sub Menu Times System Figure 33 System Times ...
Page 83: ... 83 Notes ...
Page 84: ... 84 Notes ...
Page 85: ... 85 Notes ...