Service Mode / Parameter Level
- 43 -
11.8
Calibrate Axis
11.8.1
Calibration with Axis Angle
1.
Input of the min. and max. value to be calibrated.
2.
Activate axis.
3.
Move axis accordingly (measure min/max manually).
4.
Set Increment value (inc) by „Teach“ field.
5.
With deactivated axis the according inc values can be readjusted.
The following machine values are set directly:
A
Distance to measuring system
B
Distance to pivot point
C
Blade opening at pivot point
D
Blade length
Figure 29: Axis calibration with axis angle
Set Gap
Set Angle
Note: If double gap is deactivated,
the right column does not appear
in the calibration mask.