Parameter Tables
- 66 -
13
Parameter Tables
13.1
Parameter Setting System
Table 4: Parameter list - Setting System
Function
Setting Range
Factory Setting
Customer Setting
Pressure Control
on / off
off
U at 100% pressure
0 – 10
9 V
Pressure adjust angle
0 – 100
40 %
Pressure adjust gap
0 – 100
70 %
Gap / Angle/ Pressure
hidden
locked
unlocked
unlocked
Gap 2 (right)
on / off
off
Next set stepping
without start
with start
without
without start
13.2
Parameter Times System
Table 5: Parameter list - Time System
Function
Setting Range
Factory Setting
Customer Setting
Support Delay
0 - 10
10
Support time
0 - 10
10
Support hold down
0 - 10
1.0
Delay next set
0 - 10
0.1
13.3
Parameter Sub Menu Axes
Table 6: Parameter list - Axis Backgauge
Function
Setting Range
Factory Setting
Customer Setting
Axis Type IN / OUT
Encoder - Digital
Encoder - PID+Digital
Analog - Digital
Encoder - Digital
Encoder - Digital
Encoder - Digital
Reference mode
Mode 1 / Mode 2 / Mode 3
Mode 3
Software end position
both enabled
negative disabled
positive disabled
both disabled
both enabled
Hardware end position
both enabled
negative disabled
positive disabled
both disabled
both disabled
Decimal point
1/10; 1/100; 1/1000; without
1/10
Drive signal configuration
Mode 1 … 8
Mode 2
Spindle com. Mode
without
with spindle −
with s
forced loop −
forced loop +
without
Retract Mode
Mode 1 … 8
Mode 1
Mm/Inch Mode
mm/Inch
mm