Service Mode / Parameter Level
- 50 -
11.11.1
Preparations for Activation of the Sheet Support
1.
Please check whether the software is V2.13 or higher has been installed
2.
The inputs and outputs must be assigned
(see also
11.17 Functional and Logical Assignment of Input-/Output Functions).
Inputs:
Sheet Support may have 2 or 3 positions:
if you assign the Input "support is up" and "support is down", you define a 2-position-sheet-support
if you assign in addition the Input "support in middle", you define a 3-position-sheet-support
Outputs:
Also the Outputs “support up” and “support down” must be assigned
3.
To activate the sheet support in Single- and Program-Mode, the button “Sheet Support”
(see
11.15 Soft Keys) must be used.
4.
Define the time parameter “support delay” (
11.11 Sub Menu Times System). This is the time that
must elapse between the start of the cutting process and moving the sheet support. It should be long
enough that the down holder just acts.
5.
In addition you can define the time parameter “support hold down” (
tem). This is the time that must elapse (after the cutter bar has moved up again) before the sheet sup-
port is returned to its initial position.
11.11.2
Using Sheet Support in Single and Program Mode
1.
Press button “Soft Key” (see also section
2.
Now you can:
a.
switch ON / OFF a 2-position-support
b.
use a 3-position-support with 2 (up/down) or 3 (up/middle/down) positions or switch off.
3.
In order to bring the Sheet Support in position, press “START”.
4.
When all axes are in position, the P40T is ready to cut (with sheet support and if chosen with retract
function).
11.11.3
Sheet Support Handling during Cutting Process
1.
2-position-support and 3-position-support with only 2 positions (up/down)
a.
after “start cut”, time “support delay” runs
b.
after time “support delay” elapsed, output “support down” is set
c.
P40T waits for Input "support is down”
d.
output “support down” is cleared and time “support hold down” starts
e.
if blade is in TDC (Top-Dead-Center) and time “support hold down” has elapsed,
the output “support up” is set
f.
P40T waits for Input "support is up”
g.
output “support up” is reset
Summary of Contents for P40T-002 Series
Page 49: ...Service Mode Parameter Level 49 11 11Sub Menu Times System Figure 33 System Times ...
Page 83: ... 83 Notes ...
Page 84: ... 84 Notes ...
Page 85: ... 85 Notes ...