Parameter Tables
- 71 -
13.6
Parameter Sub Menu Soft Keys
Table 18: Parameter list - Sub Menu Soft Keys
13.7
Parameter Material Table
Table 19: Parameter list - Material Table
13.8
Parameter Digitale In-/Output
Table 20: Parameter list - Digital Inputs at ST3
Table 21: Parameter list - Digital Inputs at ST4
Function
Setting Range
Factory Setting
Customer Setting
Conveyor belt
on / off
on
Autocut
on / off
off
Park position (backgauge)
on / off
off
Park position (backgauge)
3.0 …
backgauge-distance
end-position max
1101.0
Return to Operator
on / off
off
Support
on / off
off
Scrap shaft
on / off
off
Function
Setting Range
Factory Setting
Customer Setting
Sheet thickness
0.0 … 40.0
See chapter
(Material Table)
Gap
gap-distance
end-position min
…
gap-distance
end-position max
Angle
angle-distance
end-position min
…
angle-distance
end-position max
Pressure
1 … 100
Function
Setting Range
Factory Setting
Customer Setting
P3 End switch “Gauge-min”
HIGH / LOW
LOW
P4 End switch “Gauge-max”
HIGH / LOW
LOW
P5 NC
HIGH / LOW
LOW
P6 Reference start gauge
HIGH / LOW
LOW
P7 NC
HIGH / LOW
LOW
P8 NC
HIGH / LOW
LOW
P9 external START
HIGH / LOW
HIGH
P10 external STOP
HIGH / LOW
LOW
Function
Setting Range
Factory Setting
Customer Setting
P3 Piece counter
HIGH / LOW
HIGH
P4 NC
HIGH / LOW
LOW
P5 Top Dead Center
HIGH / LOW
HIGH
P6 Bottom Dead Center
HIGH / LOW
HIGH
P7 Support is up
HIGH / LOW
HIGH
P8 Support is down
HIGH / LOW
HIGH
P9 Start cut
HIGH / LOW
HIGH
P10 NC
HIGH / LOW
LOW