Service Mode / Parameter Level
- 42 -
11.7.12
U<< / U>>
This register is used to set the voltage during slow speed operation backwards / forwards.
11.7.13
U< / U>
This register is used to set the voltage during creep speed backwards / forwards.
11.7.14
Stop Mode
For the different possibilities to stop the system the P40T comes with this special register.
Stop Mode / Stop Mode manual mode:
0 = the voltage of the analog output is set to 0 V.
1 = the drive is set to a standstill with the greatest possible ramp slope.
2 = the drive is set to a standstill with the ramp slope according to the "Acceleration" parameter setting.
11.7.15
Start Mode
0 = if the axis is in the tolerance zone, it is not restarted.
1 = the start of the axis is forced in the tolerance zone.