Connections
- 65 -
12.4
Pin Assignment - 8 IO Version
ST1
Inkremental Encoder
ST2 Analog Measuring System
1 0 V / GND out
1
0 V / GND out
2 + 24 VDC out (optionally 5 VDC)
2
3,3 VDC out (reference voltage)
3 Channel A
3
Analog input “Gap1”
4 Channel B
4
do not connect
5 PE / Earth
5
PE / Earth
6 Channel A‘
6
do not connect
7 Channel B‘
7
do not connect
8 Channel Z (Indeximpuls)
8
do not connect
9 Channel Z‘ (Indeximpuls)
9
Analog input “Angle”
ST3
Inputs
1 In-/(Out)put IO-GND (0 V)*
2 In-/(Out)put IO-24 VDC**
3 End switch “gauge-min”
4 End switch “gauge-max”
5 Start cut (foot pedal)
6 Top Dead Center
7 Bottom Dead Center
8 Piece counter
9 Support is up
10 Support is down
ST5 Outputs
1 In-/(Out)put IO-GND (0 V)*
2 In-/(Out)put IO-24 VDC**
3 Drive signal 1 “gauge - forward”
4 Drive signal 4 “gauge - backward”
5 Drive signal 1 “gap1 - increase”
6 Drive signal 2 “gap1 - reduce”
7 Support up
8 Support down
9 Lift blade
10 Lower blade
ST7 Analog Output (optionally PID)
ST9 Power Supply Voltage
1 0 V / GND
1
0 V / GND
2 ± 10 VDC
2
+24 VDC (+10/−20 %)
3 PE / Earth
3
PE / Earth
ST8 Analog Output (Pressure Control)
ST12 PC Interface
1 0 V / GND
1
GND
2 ± 10 VDC
2
RS232 RX
3 PE / Earth
3
RS232 TX
NOTE!
*) Pin 1 of ST3 and ST5 are internally connected to each other and must be externally connected
to GND. It is sufficient to connect only one pin to GND (see connection examples
16).
**) Pin 2 of ST3 and ST5 are internally connected to each other and must be externally connected
to 24 VDC. It is sufficient to connect only one pin to 24 VDC (see connection examples
16).
The external ground (IO-GND) and power supply (IO-24VDC) of ST3 and ST5 are not directly connected
to the supply voltage of ST9, but there is no real galvanic isolation.