Disturbances, Maintenance, Cleaning
- 74 -
14.2
Possible Errors and their Clearance
Table 24: Possible Errors and their Clearance
Message
Required Action
Hardware end switch minimum gauge active!
check signal/connection of input / deactivate function if necessary
Hardware end switch minimum gap1 active!
check signal/connection of input / deactivate function if necessary
Hardware end switch minimum angle active!
check signal/connection of input / deactivate function if necessary
Hardware end switch minimum gap2 active!
check signal/connection of input / deactivate function if necessary
Hardware end switch maximum gauge active!
check signal/connection of input / deactivate function if necessary
Hardware end switch maximum gap1 active!
check signal/connection of input / deactivate function if necessary
Hardware end switch maximum angle active!
check signal/connection of input / deactivate function if necessary
Hardware end switch maximum gap2 active!
check signal/connection of input / deactivate function if necessary
Software end position minimum gauge fell below! check parameter or deactivate the corresponding software end posi-
tion if necessary
Software end position minimum gap1 fell below!
check parameter or deactivate the corresponding software end posi-
tion if necessary
Software end position minimum angle fell below!
check parameter or deactivate the corresponding software end posi-
tion if necessary
Software end position minimum gap2 fell below!
check parameter or deactivate the corresponding software end posi-
tion if necessary
Software end position maximum gauge exceeded! check parameter or deactivate the corresponding software end posi-
tion if necessary
Software end position maximum gap1 exceeded!
check parameter or deactivate the corresponding software end posi-
tion if necessary
Software end position maximum angle exceeded!
check parameter or deactivate the corresponding software end posi-
tion if necessary
Software end position maximum gap2 exceeded!
check parameter or deactivate the corresponding software end posi-
tion if necessary
No measuring system gauge!
check measuring system respectively the signals/connections.
No measuring system gap1!
check measuring system respectively the signals/connections.
No measuring system angle!
check measuring system respectively the signals/connections.
No measuring system gap2!
check measuring system respectively the signals/connections.
Error PID gauge!
Error PID gap1!
Error PID angle!
Error PID gap2!
Error position gauge!
Error position gap1!
Error position angle!
Error position gap2!
External stop active!
check signal/connection of input / deactivate function if necessary
Material thickness outside look-up table
Blade position detection error
Support error
Reposit axes!
Quantity reached