Service Mode / Parameter Level
- 51 -
2.
3-position-support with 3 positions (up/middle/down)
a.
after “start cut”, time “support delay” runs
b.
after time “support delay” elapsed, output “support down” is set
c.
P40T waits for Input "support in middle”
d.
output “support down” is reset
e.
P40T waits until blade turns up
f.
output “support down” is set again
g.
P40T waits for Input "support is down”
h.
output “support down” is reset and time “support hold down” starts
i.
if blade is in TDC (Top-Dead-Center) and time “support hold down” has elapsed,
the output “support up” is set
j.
P40T waits for Input "support is up”
k.
output “support up” is reset
11.11.4
Support Delay
Runtime until support is active.
11.11.5
Support Time
Runtime for total support
11.11.6
Support Holding Time
Time while support is active.
11.11.7
Delay Next Set
Time before the next step will be loaded and started.