Service Mode / Parameter Level
- 46 -
11.9.3
Mode Cutlength
OFF
via axis angle (default setting)
via time
by foot pedal
(the blade moves downwards until either the foot pedal is released,
or the BDC switch is reached. The blade then moves upwards again).
11.9.4
Pressure Blade up
Defines the pressure in % at which the knife is lifted back to the upper rest position.
11.9.5
Time Down Holder
This parameter defines the time that elapses before the down holder take effect.
11.9.6
Blade Up Delay
This parameter defines the delay time after cutting until the knife is lifted back to its rest position.
11.9.7
Acc Down
This parameter defines the duration between opening the valve and switching ON the pressure when the blade
is lowered.
11.9.8
Dec Down
This parameter defines the duration between switching OFF the pressure and closing the valve when the blade is
lowered.
11.9.9
Acc Up
This parameter defines the duration between opening the valve and switching ON the pressure when the blade
is lifted.
11.9.10
Dec Up
This parameter defines the duration between switching off the pressure and closing the valve when the knife is
lifted.
11.9.11
Delay Autocut
This parameter defines the delay time that elapses until the next cut when “Autocut” is activated.