Service Mode / Parameter Level
- 44 -
11.8.2
Calibration without Axis Angle
1.
Input of min. and max. values to be calibrated.
2.
Activate axis.
3.
Move axis accordingly (measure min/max manually).
4.
Set Increment value by the „Teach“ field.
5.
With deactivated axis the according inc values can be readjusted.
Following machine values are set directly:
A
(Left) blade opening at TDC (Top Dead Center).
B
(Right) blade opening at TDC.
C
Minimal blade opening (virtual TDC, relevant for using with cut offset)
D
If only the backgauge axis is active (gap and angle not active)…
… and the value is 0
the material thickness is considered as minimal blade opening.
… and the value is not 0
this value is the minimal blade opening.
E
If several axes are activated, this value is added to the material thickness.
F
Blade length
Figure 30: Calibration without axis angle
Set Gap
Teach values of the blade
At Cutend
Note: If double gap is deactivated,
the right column does not appear
in the calibration mask.
Summary of Contents for P40T-002 Series