Connections
- 63 -
12.2
Pin Assignment - 16 IO Version
ST1
Inkremental Encoder
ST2 Analog Measuring System
1 0 V / GND out
1
0 V / GND out
2 + 24 VDC out (optionally 5 VDC)
2
3.3 VDC out (reference voltage)
3 Channel A
3
Analog input “Gap 1“
4 Channel B
4
do not connect
5 PE / Earth
5
PE / Earth
6 Channel A‘
6
do not connect
7 Channel B‘
7
do not connect
8 Channel Z (Indeximpuls)
8
Analog input “Gap 2“
9 Channel Z‘ (Indeximpuls)
9
Analog input “Angle“
ST3
Inputs
ST4
Inputs
1 In-/(Out)put IO-GND (0 V)*
1
In-/(Out)put IO-GND (0 V)*
2 In-/(Out)put IO-24 VDC**
2
In-/(Out)put IO-24 VDC**
3 End switch “gauge-min”
3
Piece counter
4 End switch “gauge-max”
4
NC
5 NC
5
Top Dead Center
6 Reference start “gauge”
6
Bottom Dead Center
7
NC
7
Support is up
8
NC
8
Support is down
9 External START
9
Start cut (foot pedal)
10 External STOP
10
NC
ST5 Outputs
ST6 Outputs
1 In-/(Out)put IO-GND (0 V)*
1
In-/(Out)put IO-GND (0 V)*
2 In-/(Out)put IO-24 VDC**
2
In-/(Out)put IO-24 VDC**
3 Drive signal 1 “gauge - forward”
3
Drive signal 1 “gap1 - increase”
4 Drive signal 4 “gauge - backward”
4
Drive signal 2 “gap1 - reduce”
5 Drive signal 3 “gauge - fast”
5
Drive signal 1 “angle - increase”
6 Enable control “gauge”
6
Drive signal 2 “angle - reduce”
7 Support up
7
Drive signal 1 “gap2 - increase”
8 Support down
8
Drive signal 2 “gap2 - reduce”
9
NC
9
Lift blade
10 Conveyor
10 Lower blade
ST7 Analog Output (optionally PID)
ST9 Power Supply Voltage
1 0 V / GND
1
0 V / GND
2 ± 10 VDC
2
+24 VDC (+10/−20 %)
3 PE / Earth
3
PE / Earth
ST8 Analog Output (Pressure Control)
ST12 PC Interface
1 0 V / GND
1
GND
2 ± 10 VDC
2
RS232 RX
3 PE / Earth
3
RS232 TX
NOTE!
*) Pin 1 of ST3, ST4, ST5 and ST6 are internally connected to each other and must be externally connected
to GND. It is sufficient to connect only one pin to GND (see connection examples
16).
**) Pin 2 of ST3, ST4, ST5 and ST6 are internally connected to each other and must be externally connected
to 24 VDC. It is sufficient to connect only one pin to 24 VDC (see connection examples
16).
The external ground (IO-GND) and power supply (IO-24VDC) of ST3, ST4, ST5 and ST6 are not directly con-
nected to the supply voltage of ST9, but there is no real galvanic isolation.
Summary of Contents for P40T-002 Series
Page 49: ...Service Mode Parameter Level 49 11 11Sub Menu Times System Figure 33 System Times ...
Page 83: ... 83 Notes ...
Page 84: ... 84 Notes ...