Service Mode / Parameter Level
- 29 -
11.4.5
Drive Signal Configuration
With configuration of the motor signals different starting combinations for the different speeds can be set.
Drive Signals
Mode 1
3 speeds
Speed = output signals 1-3 ascending
Output 4 sets direction backwards
Output signals
1 2 3 4
Creep speed forward
X
Slow speed forward
X
X
Fast speed forward
X
X
X
Creep speed backward
X
X
Slow speed backward
X
X
X
Fast speed backward
X
X
X
X
Drive signals
Mode 2
2 speeds
Independent outputs forwards and backwards
Independent outputs fast and creep speed
Output signals
1 2 3 4
Creep speed forward
X X
Fast speed forward
X
X
Creep speed backward
X
X
Fast speed backward
X X
Drive signals
Mode 3
2 speeds
Speed = output signals 2 + 3
Output 4 set direction backwards
Output signals
1 2 3 4
Creep speed forward
X X
Fast speed forward
X
X
Creep speed backward
X X
X
Fast speed backward
X
X X