Connectors Pin Assignment
XDM-300 Installation and
Maintenance Manual
A-26 ECI
Telecom
Ltd.
Proprietary
417006-2311-0H3-A00
SHELF Alarm Connectors
The SHELF alarm connectors are 36-pin SCSI female connectors. Each
connector is connected to the ALARMS connector of an XDM-300 shelf. Refer
to ALARMS Connector (on page
) for description. The following figure
identifies the connector pins as seen when looking into the connector, and the
table lists the pin assignment for this connector.
Pin 18
Pin 36
Pin 1
Pin 19
Figure
A-13: SHELF alarm connectors pin identification
Table
A-15: SHELF alarm connectors pin assignment
Pin Name
Function
Direction
1 N/C
Not
connected
--
2
ALM_IP1
Alarm input 1, + wire
Input
3
ALM_IN1
Alarm input 1, – wire
Input
4
ALM_IP2
Alarm input 2, + wire
Input
5
ALM_IN2
Alarm input 2, – wire
Input
6
ALM_IP3
Alarm input 3, + wire
Input
7
ALM_IN3
Alarm input 3, – wire
Input
8
ALM_IP4
Alarm input 4, + wire
Input
9
ALM_IN4
Alarm input 4, – wire
Input
10
ALM_O4
Alarm output 4
Output
11 N/C
Not
connected
--
12 GND
Ground
--
13
ALM_O1
Alarm output 1
Output
14 N/C
Not
connected
--
15 GND
Ground
--
16
ALM_O2
Alarm output 2
Output
17 N/C
Not
connected
--
18 BUZZ
Buzzer
Input
19 N/C
Not
connected
--
20 GND
Ground
--
21 CRIT_COM
Critical
alarm
Output
22 N/C
Not
connected
--
23 MAJ_COM
Major
alarm
Output
24 GND
Ground
--
25 N/C
Not
connected
--
Summary of Contents for XDM-300
Page 1: ...XDM 300 Installation and Maintenance Manual Version 7 417006 2311 0H3 A00...
Page 2: ......