Before You Start
XDM-300 Installation and
Maintenance Manual
2-16 ECI
Telecom
Ltd.
Proprietary
417006-2311-0H3-A00
Alarm Cables
Alarm cables used are included in the shipment according to the site
specifications. Alarm indications are carried by the following cables:
|
Shelf alarm indication cable. One shelf alarm indication cable is required
for each XDM-300 shelf installed in the rack. One end of the cable is
always connected to the ALARMS connector on the ECU300/ECU300-F
card. Connection of the other end depends on the cable type, as follows:
xRAP-100 alarm cable. Connects to one of the SHELF connectors on
the xRAP-100.
xRAP-B alarm cable. Connects to one of the SHELF connectors on the
xRAP-B.
Client alarm cable. Connects to the client's alarm collecting facility.
|
Bay alarm cable. One bay alarm cable is required for each rack. This cable
carries the alarm indications and monitoring lines of the bay (rack). One
end of the cable is connected to the RAP, the other end is open and
connects to the client's alarm collecting facility. Two types of this cable are
available:
xRAP-100 bay alarm cable. Connects to the ALARM IN/OUT
connector on the xRAP-100.
xRAP-B bay alarm cable. Connects to the ALARMS connector on the
xRAP-B.
Management Cables
Out-of-band management communication is connected to an XDM-300 by
means of a minihub with a pair of the RJ-45 Ethernet connectors located on the
ECU300-F and ECU300 cards.
If one XDM-300 is installed, the connection is made to the management MAIN
RJ-45 connector. If more than one XDM-300 is installed in the same site, it is
possible to save the use of an external hub. In this case, the first system is
connected as explained above, and the other systems are connected in an
Ethernet daisy chain. The management MAIN connector of each system is
connected to the management PROT/LCT connector of the previous system.
Suitable standard Ethernet station cables are available from many sources.
Cables of Category 3 or better must be used. The length of the cables must not
exceed the maximum recommended for the cable type and hub port in use (up
to a few dozen meters).