Connectors Pin Assignment
XDM-300 Installation and
Maintenance Manual
A-8 ECI
Telecom
Ltd.
Proprietary
417006-2311-0H3-A00
T3_1/T4_1 and T3_2/T4_2 Connectors
The T3_1/T4_1 and T3_2/T4_2 connectors are 9-pin D-type male connectors,
each including two groups of lines:
|
Clock input (T3 2.048 MHz signal, ITU-T Rec. G.703 interface)
|
Clock output (T4 2.048 MHz signal, ITU-T Rec. G.703 interface)
The MAIN connector serves the main TMU, and the PROTECT connector
serves the standby (protection) TMU. They are connected to the site timing
reference distribution subsystem.
The following figure identifies the connector pins as seen when looking into
the connector, and the table lists their pin assignment.
Figure
A-3: T3_1/T4_1 and T3_2/T4_2 connectors pin identification
Table
A-5: T3_1/T4_1 and T3_2/T4_2 connectors pin assignment
Pin Name
Function
Direction
1 SHIELD
Shield
-
2
CK_2M_MIL
Clock input, low
Input
3 SHIELD
Shield
-
4 CK_2M_MOL Clock
output,
low
Output
5 —
Not
connected
-
6 CK_2M_MIH Clock
input,
high
Input
7 SHIELD
Shield
-
8
CK_2M_MOH
Clock output, high
Output
9 —
Not
connected
-