Equipment Installation
XDM-300 Installation and
Maintenance Manual
3-96 ECI
Telecom
Ltd.
Proprietary
417006-2311-0H3-A00
XDM-300 1:3 protection scheme
connections
The following figure shows an example of a typical 1:3 protection scheme for
an XDM-300 populated with PIM2_21 modules in the upper and lower module
cages and TPM2_3 modules in the upper and lower TPUs. The marking P in
the XDM-300 shelf designates the Protection module, and M the Main
(working) module.
Figure
3-59: XDM-300 1:3 protection scheme example
The following table shows the slot association for 1:3 protection scheme in the
XDM-300.
Table
3-13: XDM-300 1:3 I/O protection
I/O slot allocation
TPU slots
Protection Main
M1-1 and M1-2
I1
I2, I5, I6
M1-3 and M1-4
I3
I4, I7, I8
M3-1 and M3-2
I9
I10, I13, I14
M3-3 and M3-4
I11
I12, I15, I16
Summary of Contents for XDM-300
Page 1: ...XDM 300 Installation and Maintenance Manual Version 7 417006 2311 0H3 A00...
Page 2: ......
Page 8: ......