XDM-300 Installation and
Maintenance Manual
Equipment
Installation
417006-2311-0H3-A00 ECI
Telecom
Ltd.
Proprietary
3-59
Quad I/O Cards
Quad I/O cards (SIM16_4 or SIM64_XFP) can be installed in two dedicated
slots (I17, I18) called quad slots (as they occupy the space of four I/O module
slots) in the XDM-300. When quad I/O cards are not needed, these slots can be
utilized to install SIM16_1 modules by adding a mechanical adapter.
Figure
3-41: Installing a quad I/O card
N
OTE
:
When quad I/O cards or SIM16_1 modules are not
installed in slots I17, I18, the openings must be covered with
blank panels to avoid cooling air escape and comply with
electromagnetic compatibility (EMC).
To install a quad I/O card:
1.
Check that the card has not been physically damaged during shipment, and
that the antistatic protection bag of the original packaging is sealed.
2.
Remove the card from its antistatic protection packaging and perform a
visual inspection to detect damage during shipping. Report any problems.
3.
Record the hardware and software versions indicated on the card’s
identification labels.