Equipment Installation
XDM-300 Installation and
Maintenance Manual
3-86 ECI
Telecom
Ltd.
Proprietary
417006-2311-0H3-A00
Connecting Power Cables
The power cables are connected to the corresponding connectors on the
MXC300 cards.
To connect power cables:
N
OTE
:
To facilitate power cables routing, it is recommended
to start from the XDM-300 shelf towards the RAP.
1.
Connect the connector at the end of the power cable to the POWER
connector of the MXC300 in slot MXC-A, and fasten it with its two screws.
2.
Grasp the connector at the other end of the power cable, and thread it
through the opening in the left bracket of the XDM-300 shelf.
3.
Repeat steps 1 and 2 for the second power cable to be connected to the
corresponding MXC300 in slot MXC-B.
4.
Bend the cables and thread them through the side cable guides of the rack.
Pull the cables until the cable connectors are positioned against the
appropriate connectors on the RAP.
5.
Use cable ties as required to fasten the cable to the rack side rails.
N
OTE
:
The xRAP-B installation procedure is described in
Installing the xRAP-B (on page
), and the xRAP-100
installation procedure is described in Installing the xRAP-100
(on page
6.
Connect the free ends of the power cables in accordance with the rack
installation plan and the cable tags to the DC power connectors on the
RAP.
C
AUTION
:
Do not extract/insert an MXC300 card while the
DC cables are connected to it.