Equipment Installation
XDM-300 Installation and
Maintenance Manual
3-68 ECI
Telecom
Ltd.
Proprietary
417006-2311-0H3-A00
To remove a module guide from the lower row of slots:
1.
Identify the module guide you are removing and remove the screw from the
front of the guide.
2.
Gently pull the module guide out.
Figure
3-46: Removing the module guide
C
AUTION
:
Do not allow the metal part you are removing to
touch any modules or other parts of the XDM-300 cage. This
may cause a short-circuit and damage the modules.
To install a double-slot module in the modules cage:
1.
Check that the module has not been physically damaged during shipment,
and that the antistatic protection bag of the original packaging is sealed.
2.
Remove the module from its antistatic protection packaging and perform a
visual inspection to detect damage during shipping. Report any problems.
3.
Record the hardware and software versions indicated on the module’s
identification labels.
4.
Identify the assigned slot and insert the rear end of the module into the
corresponding module guides.
5.
Push the module in until it mates the chassis connectors and the front of the
module is flush with the front of the XDM-300 shelf. Make sure the two
fastening screws are free to move backward as the module slides in. If you
feel resistance before the connectors are mated, pull the module out and
repeat the procedure.