Installing Extendable Rails
In high-density installations, it may be necessary to install the xRAP above the
rack using the extendable installation rails available from ECI Telecom.
In this case, attach the extendable installation rails to the top of the rack before
installing the equipment.
Rack Grounding
Immediately after installing the rack, connect its grounding stud to the
prescribed grounding point on the site grounding bar. Use a grounding lead that
meets the Rack grounding requirements (on page
) listed in section Before
You Start.
19" Rack Installation
The XDM-300 can also be installed in European 19" racks. This is accepted
under the limitations that the rack's general dimensions are according to the
following figure. Any other European 19” rack must first be examined and
approved by ECI Telecom’s Transport Networking Division Mechanical
Department.
Top view
597
60
5.
5
66
7
Side view
60
0
597
512
62
5
35
5
597
1
9
1
2
Front view
Rear view
597
202
1
515
538
500
44
Z
Mounting angle
Foremost position
Detail Z
M
aximu
m
dis
tance
b
e
tw
een
levels
499m
m
500
44
515
538
Figure
B-4: Example of an approved European 19" rack