Connectors Pin Assignment
XDM-300 Installation and
Maintenance Manual
A-20 ECI
Telecom
Ltd.
Proprietary
417006-2311-0H3-A00
Table
A-13: SHELF alarm connectors pin assignment
Pin Name
Function
Direction
1
COMMON_F
Floating power supply common
Input
2
ALM_IP1
Alarm input 1, + wire
Input
3
ALM_IN1
Alarm input 1, – wire
Input
4
ALM_IP2
Alarm input 2, + wire
Input
5
ALM_IN2
Alarm input 2, – wire
Input
6
ALM_IP3
Alarm input 3, + wire
Input
7
ALM_IN3
Alarm input 3, – wire
Input
8
ALM_IP4
Alarm input 4, + wire
Input
9
ALM_IN4
Alarm input 4, – wire
Input
10
ALM_IP5
Alarm input 5, + wire
Input
11
ALM_IN5
Alarm input 5, – wire
Input
12
ALM_O1NO/IN6
Alarm output 1 NO/input 6, – wire
Output/Input
13
ALM_O1/IP6
Alarm output 1 common/input 6, + wire
Output/Input
14
ALM_O1NC
Alarm output 1 NC
Output
15
ALM_O2NO/IN7
Alarm output 2 NO/input 7, – wire
Output/Input
16
ALM_O2/IP7
Alarm output 2 common/input 7, + wire
Output/Input
17
ALM_O2NC
Alarm output 2 NC
Output
18 BUZ_COM
Buzzer
common
Input
19
CRIT_NC
Critical alarm NC
Input
20
CRIT_NO
Critical alarm NO
Input
21
CRIT_COM
Critical alarm common
—
22
MAJ_NC
Major alarm NC
Input
23
MAJ_COM
Major alarm common
Input
24
MAJ_NO
Major alarm NO
Input
25
MIN_NC
Minor alarm NC
—
26
MIN_NO
Minor alarm NO
Input
27
MIN_COM
Minor alarm common
Input
28 WARN_NC
Warning
alarm
NC
Input
29
WARN_COM
Warning alarm common
—
30 WARN_NO
Warning
alarm
NO
—
31
ALM_O3NO/IN8
Alarm output 3 common/input 8, – wire
—
32
ALM_O3/IP8
Alarm output 3 common/input 8, + wire
Input
33
ALM_O3NC
Alarm output 3 NC
Input
34
EXTA_SN2
External alarm sense 2
Input
35
BUZ_NO
Audio alarm activation line
Input
36
EXTA_SN1
External alarm sense 1
Input