Example:
Copy of marker blocks, definition of marker ranges direct
The content of marker bytes 10 to 19 is to be transferred to
marker bytes 20 to 29.
Parameters of BT01 function block:
Source range:
>I1 MB10
Destination range:
>I2 MB20
Number of bytes:
>NO
10
After a rising edge from 0 to 1 at coil BT01T_ the content of
MB10 to MB19 is copied to the marker bytes MB20 to MB29.
Example:
Copying of marker blocks, definition of a marker range with
offset
The content of marker bytes MB15 to MB18 is to be copied to
marker bytes MB65 to MB68.
Source range
Value of source
marker range
(decimal)
Destination
range
Value of
destination
marker range
(decimal)
MB10
42
MB20
42
MB11
27
MB21
27
MB12
179
MB22
179
MB13
205
MB23
205
MB14
253
MB24
253
MB15
17
MB25
17
MB16
4
MB26
4
MB17
47
MB27
47
MB18
11
MB28
11
MB19
193
MB29