For more information visit:
www.EatonElectrical.com
Visualization with EZD
MN05013005E
330
Screen 2:
Screen 2 is almost the same as screen 1 apart from one
addition which enables the message text element to be made
invisible via I1 (make contact bit logic). The use of the break
contact bit logic would make the element visible.
Figure 180: Make message text invisible
Screen 3:
Screen 3 is almost the same as screen 1 apart from one
addition, by which the actuation of I1 causes the first message
text element to flash and the second message text element to
be inverted.
Figure 181: Making message text flash or inverted
I1 not actuated
I1 actuated
Invisible via
I1!
Message texts
Invisible via
I1!
Display
change via I1!
Message texts
Message texts
Display
change via I1!
are six
are six