For more information visit:
www.EatonElectrical.com
Appendix
MN05013005E
412
General ambient conditions
Climatic conditions
(damp heat constant to IEC 60068-2-78; cyclical to
IEC 600618-2-30)
(cold to IEC 60068-2-1, heat to IEC 60068-2-2)
Ambient temperature
Installed horizontally/vertically
°C, (°F)
–25 to 55, (–13 to 131)
Condensation (power supply unit/CPU;
inputs/outputs)
Prevent condensation with
suitable measures
Legibility of the display (–10 to 0 °C with activated
backlight, uninterrupted duty)
°C, (°F)
–5 to 50, (–23 to 122)
Storage/transport temperature
°C, (°F)
–40 to 70, (–40 to 158)
Relative humidity (IEC 60068-2-30),
non-condensing
%
5 to 95
Air pressure (operation)
hPa
795 to 1080
Ambient mechanical conditions
Pollution degree
Power supply unit/CPU; inputs/outputs
2
Display/operating unit
3
Degree of protection (EN 50178, IEC 60529, VBG4)
Power supply unit/CPU; inputs/outputs
IP20
Display/operating unit
IP65, Type 3R, Type 12R
Display/operating unit with protective cover
IP65, Type 3R, Type 12R
Display/operating unit with protective membrane
IP65, NEMA Type 4X
(Type 3R rain-tight and
Type 12 dust-tight)
Oscillations (IEC 60068-2-6)
Constant amplitude 0.15 mm
Hz
10 to 57
Constant acceleration 2 g
Hz
57 to 150
Shocks (IEC 60068-2-27) semi-sinusoidal 15 g/11 ms Shocks
18
Drop (IEC 60068-2-31)
Drop
height
mm
50
Free fall, when packed (IEC 60068-2-32)
m
1