Page 88 of 126
198-0853-02 Rev F
A.6.4.2
Digital Input System Menu
Digital input cycle start = Off
When the inhibit input changes from a
hardware disable (inhibit lamp is on) to a
hardware enable (inhibit lamp turns off) no
action is taken.
Digital input cycle start = On
When the inhibit input changes from a
hardware disable (inhibit lamp is on) to a
hardware enable (inhibit lamp turns off) a
cycle is started (or resumed if the cycle was
paused). Use this setting for remote
operate control.
CAUTION:
This setting will cause the unit
to go to operate mode any time the inhibit
lamp turns off.
Digital input cycle stop = End
When the inhibit input changes from a
hardware enable (inhibit lamp is off)
to a hardware disable (inhibit lamp
turns on) the currently running cycle
ends.
Digital input cycle stop = Pause
When the inhibit input changes from a
hardware enable (inhibit lamp is off)
to a hardware disable (inhibit lamp
turns on) the currently running cycle is
paused.
.
.
Digital Input
System Menu
Enter the digital input system menu from
the system configuration menu.
Return to System
Configuration Menu