Page 20 of 126
198-0853-02 Rev F
Units using
Only Voltage Control and Readback
should be wired as shown below. The current
level is set to maximum using a resistor.
Typical Analog Control Wiring (Voltage Control Only)
Connector Signals
1 shield gnd
2 no connection
3 dc common
4 +12 (50ma)
5 -volt cntl in
6 +volt cntl in
7 -curr cntl in
8 +curr cntl in
9 +volt rb out
10 -volt rb out
11 + curr rb out
12 - curr rb out
1
12
6
Analog Control Connector
IN
OUT
Controller (Voltage)
4-20ma, 0-5V or 0-10V
+
-
+
-
Earth
Gnd
Shields
Shields
Approximately
560 Ohm
Resistor, ½ Watt
Jumper
Alternative to the resistor:
The current can be adjusted to
the desired value in Local
control. Then the current setting
source can be changed to host
using the procedure in section
6.3.3
. Finally when the unit is
changed to Remote control with
the RMT switch, the current
setting will be retained as long
as there is not a host to change
it.