Smart LT Manual
Dynatronix, Inc.
198-0853-02 Rev F
Page 77 of 126
A.4 Display Select Menu
.
.
.
.
.
.
.
.
.
.
Enter the display select menu from any run screen (meters, totalizer,
cycle, or diagnostics) by pressing and holding both encoder switches
for one second.
Once “diSP” “SEL” is displayed release
both encoder switches.
First screen showing total
amp hours
Second screen showing total
amp hours
Third screen showing total amp
hours. If the units were amp
minutes then this screen would
show “min” rather than “Hr”.
Last Screen, blinking ‘Lo’
to indicate the lower four
digits of the total amp
hours are displayed.
Rotate the voltage encoder
to change to ‘Hi’ and show
the upper four digits.
Pressing the voltage encoder
displays the voltage setting and
enables edit of the voltage setting.
Rotate the voltage encoder to
change digit values, press the
voltage encoder to select digits.
Pressing the current encoder
displays the current setting and
enables edit of the current setting.
Rotate the current encoder to
change digit values, press the
current encoder to select digits.
After the settings are not adjusted
for a short period of time the
display returns to the meter values.
First screen showing ATC
amp hours remaining in the
currently running cycle. If
the currently running cycle
were an RTC controlled
cycle then “RTC” would
be displayed rather than
“ATC”.
Second screen showing ATC
amp hours remaining in the
currenlyt running cycle.
Last screen showing ATC amp
hours remaining in the
currenlyt running cycle. If the
units were amp minutes then
this screen would show “min”
rather than “Hr”.
Heat sink temperature = 25C
Heat sink temperature = 77F
Fan speed = 55%
Meter Run
Screen
Totalizer
Run Screen
Cycle Run
Screen
Diagnostic
Run Screen
Pressing the current encoder
displays the target ATC/RTC
setting and allows direct edit of
the target setting (standby
only). After the setting is not
changed for a short period of
time the display returns to the
cycle count down.
Voltage and current
meter run screen.