A.2.2 Power On Resume Cycle
.
.
.
.
Unit Power On
Resume Operate in 04 Seconds
Pressing the voltage encoder or the OPER/STBY button will abort
the count down and keep the cycle paused so that it can be
manually resumed later.
At the end of the count down the cycle resumes where it was
when the unit was powered off.
Meters Run Screen:
In this example two possibilities are shown.
In the branch where the meter values are both zero
the count down to operate was aborted by the user
and the cycle remains paused (output disabled,
OPER/STBY lamp blinking).
In the branch where the meter values are not zero the
count down to operate completed and the cycle
resumed (output enabled, OPER/STBY lamp on
steady).
Power Failure:
Output is disabled, unit is powering off.
Unit Power Off
Four
Seconds
Power
Lost
Power
OK
Power On Start = Last
This shows the display at power on after the unit was powered off while a cycle
was running (unit was in operate).
See the unit start system menu for details on how to change the power on start
configuration.
Power
OK
Power
Lost