Smart LT Manual
Dynatronix, Inc.
198-0853-02 Rev F
Page 21 of 126
6. Operating Procedures
6.1. Front Panel Controls
6.1.1. Displays
In addition to providing current and voltage meters the displays can display other supply
information. The displays can show numeric parameter values or text messages.
6.1.1.1.
Run Screens
Run screens are shown during normal supply operation. An example of a run screen is the
meters run screen which displays the output current and output voltage and allows for display and
edit of the current and voltage settings. Other examples of run screens include totalizer time,
cycle time, and diagnostics. The ‘SET’ lamp is off when a run screen is displayed.
6.1.1.2.
Menus
Menus can be displayed to configure the power supply. The unit configuration menu contains
items that are generally only set when a power supply is initially installed. The setup menu
contains general cycle configuration such as selecting RTC or ATC control and setting current or
voltage tolerances. The display select menu provides a method to select which run screen is
displayed. The ‘SET lamp is on steady when a menu is displayed. The ‘SET’ lamp blinks on and
off when a parameter is displayed.
6.1.2. Encoder Functionality
The encoders can be turned clockwise or counter-clockwise. Each encoder also functions as a
momentary switch when it is pushed in.
OVERTEMP
FAULT
INHIBIT
1 2 3 4
4 3 2
RMT
LCL
OPER
STBY
VOLTS
AMPS
SET
Air Inlet
Setting Indicator
Operate / Standby Switch
Remote / Local Switch
Main Power Switch
Current Meter
Voltage Meter
Voltage Encoder & Indicator
Current Encoder & Indicator
Error / Status Indicators