Page 14 of 126
198-0853-02 Rev F
OUTPUT PROTECTION
The internal controller will not accept commands that
will exceed the output rating of the power supply.
CONTROLS
Smart LT Front panel (display, encoders, switches).
Host Port (RS485)
Optional Analog Interface.
ENVIRONMENTAL CONDITIONS
INDOOR USE ONLY
Operating temperature: 0 - 40C
Non-condensing humidity conditions 15-90% RH
Storage temperature: -20 - 85C
LOAD REGULATION
Current: : ±0.5% of maximum current rating for the
power supply from 10% -100% load
Voltage: : ±0.5% of maximum voltage rating for the
power supply from 10% - 100% load
LINE REGULATION
For line conditions as listed in 4.1
Current: : ±0.5% of maximum current rating for the
power supply
Voltage: : ±0.5% of maximum voltage rating for the
power supply
RIPPLE
120mVrms maximum throughout operating range
COOLING
Variable fan speed forced air cooling: in through front,
out through rear. Allow 2 inches (51mm) minimum
clearance on front and rear of unit.
ENCLOSURE
Half-rack enclosure, 316 Stainless Steel
SIZE
3.43” (87.1mm)H x 8.45” (214.6mm)W x 16” (406mm)D
(18” (457mm)D including controls and connectors)
WEIGHT
Approximately 17lbs (7.7kg).