
Smart LT Manual
Dynatronix, Inc.
198-0853-02 Rev F
Page 119 of 126
B.1.18
Unit Info Command “u”:
@AA.a
Sync character (@) and unit address, AA = Unit ID (0 to 99; 0 is a global ID), a =
Channel ID (always 0)
u0
Command character and Type
– 0=read, 1=set(n/a), 2=activate(n/a), 3=ack,
4=nak
#24,
Number of fields character and number of fields after the comma, excluding CRC
00,
Model Type Start model types start at 20. 20 = 1200W, 21 = 36kW
mdl
0123456,
serial number
– 01 is 2 digit year, 234 is day of year, 56 is unit build count
sn
750,
Amp Rating
– amps
fir
750,
Volt Rating
– volts
fvr
750,
Amp Rating
– amps (second channel, if present)
fir
750,
Volt Rating
– volts (second channel, if present)
fvr
6000,
unit on time
– minutes
ton
3000,
unit operate time
– minutes
topr
12345,
Unit amp hours ch1
ahr
0,
Unit amp hours ch2
ahr
3,
LT control panel firmware major version number
– 0-255 [in PT# 200-
1458-V301 the major version number is 3]
av1
0,
LT control panel firmware minor version number
– 0-255 [in PT# 200-
1458-V301 the minor version number is 1 (01)].
av2
1,
LT control panel firmware revision number
– 0-255 [the revision is not part
of the part number]
av3
6,
LT Boot loader major version number
– 0-255 [in PT# 200-0458-V601 the
major version number is 6]
bv1
0,
LT Boot loader minor version number
– 0-255 [in PT# 200-0458-V601 the
minor version number is 1 (01)]
bv2
1,
LT Boot loader revision number
– 0-255 [the revision is not part of the part
number]
bv3
200,
LT control panel firmware part number class [in PT# 200-1458-V301, the
class is 200]
ap1
1458,
LT control panel firmware part number type [in PT# 200-1458-V301, the
type is 1458]
ap2
301,
LT control panel firmware part number version [in PT# 200-1458-V301 the
version is 301]
ap3
200,
LT boot loader firmware part number class [in PT# 200-0458-V601, the
class is 200]
bp1