5. Installation Instructions
5.1. Power Input
5.1.1. Input Power Requirements
The input power and output capacity of each rectifier is specified on the equipment serial tag
located on the back of the unit. The power supply has a universal input, 100-240VAC, 50-60Hz,
single phase. Derate maximum output power to 1000W for input voltages less than 100Vac.
5.1.2. Input Power Connection
Make sure the Main Power Switch is in the OFF (0) position. Plug the female end of the power
cord into the back of the power supply. Connect the male end of the power cord* to the correct
supply in accordance with U.L. and/or OSHA specifications.
*
If power supply does not come equipped with a male plug, use Interpower NEMA 6-20 (250Vac,
20A) P/N: 88030180 or equivalent.
5.2. Mounting
Place the LT1200X Series power supply on a shelf capable of accepting a 1/2 rack mount
package.
Cooling is front to rear unless power supply is equipped with a rear filter cooling is from back to
front. Do not block airflow to the unit. Leave at least 2 inches (5cm) in front of and behind the
power supply for adequate ventilation. Place the unit in an area which has adequate ventilation to
prevent condensation. Do not spray liquids on or inside power supply. Keeping units away from
corrosive plumes will help prolong the life of your capital investment.
Host Port
Inhibit Connector
Power Inlet
Option Card Connector
Fan Cover & Rear Air Vent
(Air filter if equipped)
Output Bus-Bars