EN
MalFunCTIon TaBlE
DiBO 58
Malfunction table
at a possible malfunction one can consult the table mentioned below and if you
obtain on this basis no solution, we advise to contact a DiBo technician and/or
a recognized DiBo representative.
MALFUNCTION
CAUSE
SOLUTION
Machine does not start
• Electrical supply not connected
• net fuse defect
• Main switch on “0”
• Rest malfunctions
• Connect the electrical supply
• Check net fuse
• put main switch on “1”
• Consult an expert
no water pressure
• To few water inlet
• Filter stuffed-up
• Repair water inlet
• Clean/replace filter cartridge
Instable and to weak pressure
• air in water supply (leaks in water
supply)
• nozzle or lance stuffed-up or worn-
out.
• pressure regulator defect
• Rest malfunctions
• put machine completely without
power! Repair leaks in supply.
• Clean or replace
• Consult an expert
• Consult an expert
Water in product tank
• non return valve in filter defect
• Replace suction filter
no additions of products
• Suction pipe
• Suction filter stuffed-up
• product tank empty
• Spray pressure to high
• Repair suction pipe
• Clean suction filter
• Refill or replace tank
• lower spray pressure
no hot water SBh-D
no hot water SBJ-G
• Main switch not on position “2”
• Burner switch not on position “1”
• heat resistors defective
• Temperature sensor defective
• Rest malfunctions
• put main switch on position “2”
• put burner switch on position “1”
• Consult an expert
• Consult an expert
• Consult an expert
aerator does not turn
SBh-D
SBh-G
• net fuse defect
• Main switch not on position “2”
• Burner switch not on position “1”
• Electrical motor defective
• Check net fuse
• put main switch on position “2”
• put burner switch on position “1”
• Consult an expert
Burner does not start
• no fuel
• rest malfunctions
• Refill fuel
• Consult an expert
hp pump pulse
• leak or congestion in supply
conduit
• To much air present
• Clean/replace/repair
• De-aeration of cleaner
Summary of Contents for SBH-G-D
Page 2: ......
Page 4: ......
Page 54: ...NL Brander BR1000G instructies en voorschriften DiBO 54 31...
Page 55: ...Brander BR1000G instructies en voorschriften NL DiBO 55 32...
Page 56: ...NL Brander BR1000G instructies en voorschriften DiBO 56 33...
Page 57: ...Brander BR1000G instructies en voorschriften NL DiBO 57 34...
Page 66: ......
Page 68: ......
Page 98: ......
Page 100: ......
Page 150: ...EN Combustion chamber gas heated instructions regulations DiBO 54 31...
Page 151: ...Combustion chamber gas heated instructions regulations EN DiBO 55 32...
Page 152: ...EN Combustion chamber gas heated instructions regulations DiBO 56 33...
Page 153: ...Combustion chamber gas heated instructions regulations EN DiBO 57 34...
Page 162: ......
Page 164: ......
Page 206: ...DE Brennerkammer BR1000G Anweisungen Vorschriften DiBO 46 23 30 Schaltplan BR1000G...
Page 214: ...DE Brennerkammer BR1000G Anweisungen Vorschriften DiBO 54 31...
Page 215: ...Brennerkammer BR1000G Anweisungen Vorschriften DE DiBO 55 32...
Page 216: ...DE Brennerkammer BR1000G Anweisungen Vorschriften DiBO 56 33...
Page 217: ...Brennerkammer BR1000G Anweisungen Vorschriften DE DiBO 57 34...