6 - 4 6
Modulon DPH Series
(QHUJ\5HF\FOH0RGH7XUQRႇ3URFHGXUHV
WARNING:
Energy Recycle mode is only applicable to single input and single
unit application.
1
In Energy Recycle mode, the LCD shows the following screen (
)LJXUH
and the
tri-color LED indicator illuminates yellow.
Energy
Recycle
POWER FLOW
Maintenance
Bypass
Bypass
Mains
MEASUREMENT
Power Flow
UPS-1.1
SETUP
MAINTENANCE
2
WARNING
LOG IN
User
Load
0 %
0 %
0 mins
Power Flow
Summary
EMS
System Status
10:15
May 25,2018
ON/ OFF
Button
)LJXUH(QHUJ\5HF\FOH0RGH6FUHHQ 212))%XWWRQ/RFDWLRQ
2
Tap the ON/ OFF Button (
) and the following screen will pop up to ask if you want
WRSRZHURႇWKH836¶VLQYHUWHU3OHDVHVHOHFW
YES
'.
MEASUREMENT
Power Flow
UPS-1.1
SETUP
MAINTENANCE
No
Yes
LOG IN
User
POWER OFF ?
Transfer to Bypass without Protection!
Energy
Recycle
2
WARNING
10:15
May 25,2018
)LJXUH3RZHURII5HPLQGHU6FUHHQ