6
|
Technical data
Service manual
165
250D7Y1B
Sky Air Advance-series
ESIE19-13A – 2020.05
Wiring
symbol
Component name
Thermistor
diameter
Marking
color
Component
connector
PCB connector
Voltage Routing (views)
R1T
Air thermistor
5 mm
None
White
X18A
White
Low
J-L-N-P-U-AD
R3T
Suction thermistor
6 mm
Green
White
X30A
White
Low
L-M-P
R4T
Heat exchanger
thermistor
7 mm
Red
F-J-L-N-P
R5T
Heat exchanger
(middle) thermistor
6 mm
White
J-L-N-P
R6T
Refrigerant liquid
thermistor
7 mm
Blue
P-W
R2T
Discharge pipe
thermistor
8 mm
Yellow
Red
X29A
Red
Low
P-W-AB
R7T
Compressor body
thermistor
8 mm
None
P-W
Y1E
Electronic expansion
valve (main)
-
-
White
X21A
White
Low
L-P-V
Y3E
Electronic expansion
valve (liquid
injection)
-
-
Blue
X22A
Blue
Low
L-P-V
S1PL
Low pressure switch -
-
Red
X31A
Red
Low
K-L-P
S1PH
High pressure switch -
-
White
X2A
White
Low
K-L-P-Q
Y1S
4‑way valve
-
-
Blue
X9A
Blue
High
S-AB
Y3S
Solenoid valve
-
-
Pink
X8A
Pink
High
S-AB
M1F
Fan motor
-
-
White
X1A
White
High
A-C-D-AA
E1HC
Cranckase heater
-
-
Grey
X11A
Grey
High
G-AB
M1C
Compressor
-
-
Red,
White,
Blue
U, V, W None
High
K-AB
Summary of Contents for Sky Air Advance RZA200D7Y1B
Page 1: ...Service manual Sky Air Advance series RZA200D7Y1B RZA250D7Y1B ...
Page 190: ......
Page 191: ......
Page 192: ...ESIE19 13A 2020 05 Copyright 2020 Daikin Verantwortung für Energie und Umwelt ...