DDM Bias Current Threshold Settings
This window is used to configure the threshold of the bias current for specific ports on the Switch.
To view the following window, click
System
Configuration > Port Configuration > DDM > DDM Bias Current
Threshold Settings
, as shown below:
Figure 2-8 DDM Bias Current Threshold Settings window
The fields that can be configured are described below:
Parameter
Description
Unit
Select the unit to be configured.
(EI Mode Only)
From Port / To Port
Select a range of ports to be configured.
High Alarm (0-131)
This is the highest threshold for the alarm. When the operating parameter rises above
this value, action associated with the alarm will be taken.
Low Alarm (0-131)
This is the lowest threshold for the alarm. When the operating parameter falls below
this value, action associated with the alarm will be taken.
High Warning (0-131)
This is the highest threshold for the warning. When the operating parameter rises
above this value, action associated with the warning will be taken.
Low Warning (0-131)
This is the lowest threshold for the warning. When the operating parameter falls below
this value, action associated with the warning will be taken.
Click the
Apply
button to accept the changes made.