xStack® DGS-3120 Series Layer 3 Managed Gigabit Ethernet Switch Web UI Reference Guide
160
Parameter
Description
LLDP-MED Log
State
Click to enable or disable the log state of LLDP-MED events.
Fast Start Repeat
Count (1-10)
Enter a value between 1 and 10 for the fast start repeat count. When an LLDP-MED
Capabilities TLV is detected for an MSAP identifier not associated with an existing
LLDP remote system MIB, then the application layer shall start the fast start
mechanism and set the ‘medFastStart’ timer to ‘medFastStartRepeatCount’ times 1.
The default value is 4.
Click the
Apply
button to accept the changes made for each individual section.
LLDP-MED Port Settings
This window is used to enable or disable transmitting LLDP-MED TLVs.
To view the following window, click
L2 Features > LLDP > LLDP-MED > LLDP-MED Port Settings
, as shown
below:
Figure 4-124 LLDP-MED Port Settings window
The fields that can be configured are described below:
Parameter
Description
Unit
Select the unit you want to configure.
(EI and SI Mode Only)
From Port / To Port
Select the port range to use for this configuration.
Port Description
Use the drop-down menu to enable or disable the Port Description option.
NTCS
Use the drop-down menu to enable or disable Notification Topology Change Status.
State
Use the drop-down menu to enable or disable transmit LLDP-MED TLVs, and tick the
check boxes of the TLV types that the LLDP agent should transmit. TLV types are
Capabilities
,
Network Policy
, and
Inventory
. Tick the
All
check box to select all TLV
types.