Guidelines for Making Changes to Current Installation
Writer: Pamela King Project: SMART-2DH Array Controller Reference Guide Comments: 295469-002
File Name: C-CH02.DOC Last Saved On: 2/27/98 11:25 AM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
Figure 2-5.
Interim four-array state
Controller 1
Controller 2
ID6
ID6
z
ID5
ID5
y
Array A
ID4
ID4
x
ID3
d
ID3
ID2
c
ID2
ID1
b
Array A
ID1
ID0
a
ID0
Figure 2-6.
Failed arrays removed; arrays on separate controllers
To restore an array to its original controller, make sure the conditions for
moving drives are met. Then:
IMPORTANT:
These steps must be followed EXACTLY. Any deviation or
mistake could result in the loss of all data across all moved arrays.
1. Power system OFF.
2. Move the array back to its original controller, but retain its drive
position as it was in the consolidated configuration.
3. Power system ON.
4. Each controller will indicate a 1789 POST message that drives are
missing. Press F2 to fail the missing drives.
5. Run Array Configuration Utility and remove the appropriate “failed”
arrays.
6. Reboot the system.