POST Error Messages
continued
1797
Slot x Drive Array - Array Accelerator Read
Error Occurred. Data in Array Accelerator has
been lost. Array Accelerator is disabled.
Replace the Array Accelerator or the
SMART-2DH Controller. Restore data from
backup.
1798
Slot x Drive Array - Array Accelerator Self-
Test Error Occurred. Array Accelerator is
disabled.
Replace the Array Accelerator or the
SMART-2DH Controller.
1799
Slot x Drive Array - Drive(s) Disabled due to
Array Accelerator Data Loss.
Select
F1
to continue with logical drives
disabled.
Select
F2
to accept data loss and to reenable
logical drives.
Data stored in the Array Accelerator has been
lost, therefore the drives have been temporarily
disabled. Press
F2
to acknowledge the data
loss and reenable the logical drives. Restore
data from backup.