POST Error Messages
continued
1774
Slot x Drive Array - Obsolete data found in
Array Accelerator. Data found in accelerator
was older than data found on drives.
Obsolete data has been discarded.
(RESUME =
F1
KEY)
Data found in Array Accelerator is older than
data found on drives due to drives having been
disconnected, used on another controller, and
then reconnected. Press
F1
to discard older
data.
1775
Slot x Drive Array - ProLiant Storage System
Not Responding SCSI Port (y): Check storage
system power switch and cables. Turn the
system power off while checking the
ProLiant power and cable connections, then
turn the system power back on to retry.
(RESUME =
F1
KEY)
Turn off power to system. Check external
ProLiant power switch - external drives must
all be powered up before or at the same time
as the main system. Check cables. If retry does
not help, try replacing the cable, ProLiant
firmware, ProLiant backplane, or the SMART-2
Controller.
1776
Slot x Drive Array - SCSI Port (y) Termination
Problem Detected.
(RESUME =
F1
KEY)
The termination power signal for the specified
SCSI port was shorted to ground. Termination
power was automatically turned off to prevent
damage to the internal hardware.
Turn off the server power and check the
cabling to the specified SCSI port. Replace
damaged cables/faulty SCSI devices attached
to cable.
continued