EXTender 1100A Switch and Remote Module System Administrator’s
Guide
66
the only log messages that would
not
be saved
are the Debug and Trace messages
Dependencies none
Reset Stats
Path Gateway
(Remote) ->Utilities->System
Description
Rests all the system statistical information.
Usage
Used to “clean up” the system statistics and to
help pinpoint problems should they occur.
Dependencies none
Set Enet Mode
Path Gateway
(Remote) ->Utilities->System
Description
Used to set the Enet network parameters.
Usage
The administrator can set the Enet mode to Auto
Detect, 10Mb – Half Duplex, 10Mb – Full Duplex,
100Mb – Half Duplex, 100Mb – Full Duplex
Dependencies
Valid IP address must be configured and Telnet
must be enabled.
Size (Log)
Path
Gateway (Remote) ->Configuration->Log
Description
When the log file becomes full the log messages
become overwritten by new messages. The
administrator has the ability to increase the log
size if required. Accepted log file sizes are 4096
to 131072.
Usage
Limits or increases the number of log messages.
Dependencies none
Table 3: Other IP Parameters
Document Number: M-1100A-MUC
Version: Rev AG