Physical Installation
Switch Module (right side of Figure 2 – previous page):
1. Place the unit in the destination location. The Switch Module can either be wall
mounted or placed on any desktop.
2. Connect the supplied RJ-45 to DB-9 Console cable between the console (COMM)
port and a PC communications (COM) port.
3. Prepare to connect the supplied RJ-45 to RJ-11 cable between Port on the rear of the
Switch Module and a port on the PBX. Do NOT connect to the PBX until the Setup
Wizard has been run.
4. Connect the LAN port to the LAN with an RJ-45 cable (optional configuration method).
5. Connect the supplied RJ-11 to RJ11 cable between the analog line provided by the
PSTN to the Telco port on the rear of the Switch Module.
Do not apply power to the units until instructed to do so. An improperly configured
Switch Module or Remote Module can cause damage to the units, telephone sets or
PBX line cards.
Remote Module (left side of Figure 2 – previous page):
!
1. Place the unit in the destination location. The Remote Module can either be wall
mounted or placed on any desktop.
2. Connect the supplied RJ-45 to DB-9 Console cable between the console (COMM)
port and a PC communications (COM) port.
3. Prepare to connect the supplied RJ-45 to RJ-11 cable between the Phone port on the
rear of the Remote Module and a supported digital set. Do NOT connect a telephone
until the Setup Wizard has been run.
4. Connect the LAN port to the LAN with an RJ-45 cable (optional configuration method).
5. Connect the supplied RJ-11 to RJ11 cable between the analog line provided by the
PSTN to the Telco port on the rear of the Switch Module.
Do not apply power to the units until instructed to do so. An improperly configured
Switch Module or Remote Module can cause damage to the units, telephone sets or
PBX line cards.
!
Document Number: M-1100A-MUC
Version: Rev AG
© Copyright 2008 Citel plc All Rights Reserved