EXTender 1100A Switch and Remote Module System Administrator’s
Guide
18
4 C
ONNECTING TO THE
S
WITCH
M
ODULE
AND
R
EMOTE
M
ODULE
This chapter provides information for connecting to the Switch Module and the Remote
Module. The Switch and Remote units’ Management Console (MC) and/or Management
Browser (MB) can be accessed with a PC or terminal connected. The Remote unit’s
Telephone Management Interface (TMI) can be accessed via the Digital phone.
A generic VT100 ETI application is needed to communicate with the Switch Module
and/or Remote Module (this document will refer to examples using Microsoft
HyperTerminal).
Management Console
The Management Console provides access to a full configuration and diagnostic and
command structure.
Direct Serial Connection
This section describes connecting to the Management Console using Microsoft
HyperTerminal. You may use a different terminal application if you are familiar with its
use.
Only use the commands listed and described in this document unless otherwise instructed
by Citel Technologies. Incorrect command use may prevent use of the Switch Module and
Remote Module.
1. Start a HyperTerminal session.
a) On a default installation of Windows XP, for example, from the
Start
menu select
Programs
,
Accessories
,
Communications
and finally
HyperTerminal
.
2. Enter a name for the new connection in the Name box: for example, Switch (or
Remote).
3. Select the COM port you are using from the options in the Connect drop-down list.
4. Check the configuration of the communications port and make sure the settings are
as follows:
Bits per second
9600
Data bits
8
Parity None
Stop bits
1
Flow Control
None
5. Plug the power supply in to the Switch Module and/or Remote Module and allow it to
complete the boot sequence.
Document Number: M-1100A-MUC
Version: Rev AG
© Copyright 2008 Citel plc All Rights Reserved