EXTender 1100A Switch and Remote Module System Administrator’s
Guide
Document Number: M-1100A-MUC
Version: Rev AG
© Copyright 2008 Citel plc All Rights Reserved
36
Path:
Gateway ->Configuration->Port
►
Refer to page
44
for full details.
8. Modify Modem Settings. Certain site conditions may require changing the default
Modem Settings. Administrator can change the Connect Rate, Leased Line, Pulse
dialing or Init String for specific site needs. See the Switch Module
Advanced
Connect Parameters – Modem Settings
and Remote Module
Advanced Connect
Parameters – Modem Settings
for full details.
Path:
Gateway (and Remote)->Configuration->Connect->Modem_Settings
TMI Path:
(Remote Only)->Set Config->Modem Menu
►
Refer to page
55
or full details
.
9. Set Dialback. If enabled, the Remote module will initiate connection to Switch
Module, then the network connection is torn down and the Switch module will connect
to the Remote module. This feature is used to have network connection calls
originated (and are subsequently billed) from the PBX location and not from the
Remote Module location. See the Remote section for full details.
Path:
Remote->Configuration->Connect->Dialback
TMI Path:
(Remote Only)->Set Config->Connect Menu->Dialback
►
Refer to page
55
or full details
.
Path:
Remote->Configuration->Connect->Dial_Numbers->Remote_Number
TMI Path:
(Remote Only)->Set Config->Connect Menu->Remote Number
►
Refer to page
55
or full details
.
10. Set the IP parameters to allow remote administration of the Switch Module and
Remote Module over the IP network. See the Switch Module
Advanced IP
Parameters – LAN Address
and Remote Module sections for full details.
Path:
Gateway (and Remote) ->Configuration->IP->LAN->Address
►
Refer to page
47
and page
57
for full details.
11. Enable Telnet and FTP for remote configuration and upgrading of the software. See
the Switch Module Advanced IP Parameters – Telnet and FTP and Remote Module
Advanced IP Parameters – Telnet and FTP sections for full details.
Path:
Gateway (and Remote) ->Configuration->IP->LAN
►
Refer to page
47
and page
57
for full details.
FTP should always be disabled when not performing a software upgrade or file transfer to
and from the units.
12. The DNS parameter allows the System Administrator to find the Switch Module by an
assigned name instead of IP address. See the Switch Module
Advanced IP
Parameters – DNS
and Remote Module
Advanced IP Parameters – DNS
sections for
full details.
Path:
Gateway (and Remote) ->Configuration->IP->DNS
►
Refer to page
50
and page
Error! Bookmark not defined.
full details.
13. Provide a system name making it easier to identify the unit when administering
multiple units. See the Switch Module
Advanced System Parameters – System
and
Remote Module
Advanced System Parameters – System Settings
sections for full
details.
Path:
Gateway (and Remote) ->Configuration->System